Underfloor Heating Cable S-cable
Home / Underfloor Heating Cable And Mat / Underfloor Heating Cable / Underfloor Heating Cable S-cable /

Constant Heat Cable 230V Floor Heating Cable House Heat System

Constant Wattage Heating Cable

Constant Heat Cable 230V Floor Heating Cable House Heat System

  • Brand:

    Huanrui
  • Power Ouput:

    10W/m,15W/m
  • Min. Installation Temperature:

    5°C
  • Rated Voltage:

    220V/230V
  • Applicable areas :

    Europe
  • Application:

    Residential floor warming
  • Min.bending radius:

    6D
  • Certifications:

    CE EAC TUV CSA


Product advantages

1.Durable and strong structure

2.High water-proofness.  IP68

3.Long working life

4.25years warranty

5.Small size ,no increase in floor thickness

6.100% screened with Zero EMF

7.100% tested before delivery

8.Free of maintenance


Features and applications

• Residential indoor floor warming.

• Workable in humid places such as bathroom.

• Applicable for flooring material like concrete, ceramic tile, marble, wood.

• Easy installation for indoor whole and partial warming systems for floor and wall warming.

• 2.8mm in diameter; lower height, cost-saving.


Part Number

Length/

m

OutputPower/W

Resistance/ Q

S-cable15-150

10

150

352.7

S-cable15-225

15

225

235.1

S-cable15-300

20

300

176.3

S-cable15-375

25

375

141.1

S-cable15-450

30

450

117.6

S-cable15-525

35

525

100.8

S-cable15-600

40

600

88.2

S-cable15-750

50

750

70.5

S-cable15-900

60

900

58.8

S-cable15-1050

70

1050

50.4

S-cable15-1200

80

1200

44.1

S-cable15-1350

90

1350

39.2

S-cable15-1500

100

1500

35.3

S-cable15-1800

120

1800

29.4


Part Number

Length/

m

Power Output/W

Resistance/Q

S-cable10-100

10

100

529.0

S-cable10-150

15

150

352.7

S-cable10-200

20

200

264.5

S-cable10-250

25

250

211.6

S-cable10-300

30

300

176.3

S-cable10-350

35

350

151.1

S-cable10-400

40

400

132.3

S-cable10-450

45

450

117.6

S-cable10-500

50

500

105.8

S-cable10-600

60

600

88.2

S-cable10-700

70

700

75.6

S-cable10-800

80

800

66.1

S-cable10-900

90

900

58.8

S-cable10-1000

100

1000

52.9

S-cable10-1200

120

1200

44.1


Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
Constant Wattage Heating Cable

The HRDVT is a cable designed to prevent snow and ice accumulation around the home or facility, such as driveway, walkways and stairs and so on.

Learn More
Touch Screen Period Programming Thermostat

This type electronic thermostat for mounting in standard wall box.

Learn More
Constant Wattage Heating Mat

HRDVCM underfloor heating mat uses a twin conductor heating cable for easy installation, and mat is designed for installation into thin adhesive beds, leveling compounds or thin screed beds beneath tiled and wooden floor.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications: •    Round-shape structure, flexible installation. •    About 3.6 mm diameter, convenient for installation. •    Twin conductor structure with one end cold lead for easy installation. •    Zero EMF. •    Can be used safely in wet conditions like bathroom. •    Quick and easy installation. •    Durable structure, long service life requiring no maintenance. •    15-year warranty for quality only, not including wrong installation and misuse.   Warranty: 15 years limited warranty against defect in material, design and workmanship. 120V Length Heating area  Total Power/W  (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-60-1 5.05 16.5 5.5 4.1 60 0.5 240.0 HRVC-120-1 10.1 33.0 10.9 8.3 120 1.0 120.0 HRVC-180-1 15.1 49.5 16.4 12.4 180 1.5 80.0 HRVC-240-1 20.1 66.0 21.8 16.6 240 2.0 60.0 HRVC-300-1 25.1 82.5 27.3 20.7 300 2.5 48.0 HRVC-360-1 30.2 99.0 32.7 24.8 360 3.0 40.0 HRVC-420-1 35.2 115.5 38.2 29.0 420 3.5 34.3 HRVC-480-1 40.2 132.0 43.6 33.1 480 4.0 30.0 HRVC-540-1 45.3 148.5 49.1 37.2 540 4.5 26.7 HRVC-600-1 50.3 165.0 54.5 41.4 600 5.0 24.0 HRVC-720-1 60.4 198.0 65.5 49.7 720 6.0 20.0 HRVC-840-1 70.4 231.0 76.4 57.9 840 7.0 17.1 HRVC-960-1 80.5 264.0 87.3 66.2 960 8.0 15.0 HRVC-1080-1 90.5 297.0 98.2 74.5 1080 9.0 13.3 HRVC-1200-1 100.5 330.0 109.1 82.8 1200 10.0 12.0 HRVC-1320-1 110.6 363.0 120.0 91.0 1320 11.0 10.9 HRVC-1440-1 120.7 396.0 130.9 99.3 1440 12.0 10.0 HRVC-1560-1 130.8 429.0 141.8 107.6 1560 13.0 9.2 HRVC-1680-1 140.8 462.0 152.7 115.9 1680 14.0 8.6 HRVC-1800-1 150.9 495.0 163.6 124.1 1800 15.0 8.0 240V Length Heating area   Total Power/W (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-120-2 10.1 33.0 10.9 8.3 120 0.5 480.0 HRVC-180-2 15.1 49.5 16.4 12.4 180 0.8 320.0 HRVC-240-2 20.2 66.0 21.8 16.6 240 1.0 240.0 HRVC-300-2 25.1 82.5 27.3 20.7 300 1.3 192.0 HRVC-360-2 30.2 99.0 32.7 24.8 360 1.5 160.0 HRVC-420-2 35.2 115.5 38.2 29.0 420 1.8 137.1 HRVC-480-2 40.2 132.0 43.6 33.1 480 2.0 120.0 HRVC-540-2 45.3 148.5 49.1 37.2 540 2.3 106.7 HRVC-600-2 50.2 165.0 54.5 41.4 600 2.5 96.0 HRVC-720-2 60.4 198.0 65.5 49.7 720 3.0 80.0 HRVC-840-2 70.4 231.0 76.4 57.9 840 3.5 68.6 HRVC-960-2 80.4 264.0 87.3 66.2 960 4.0 60.0 HRVC-1080-2 90.6 297.0 98.2 74.5 1080 4.5 53.3 HRVC-1200-2 100.6 330.0 109.1 82.8 1200 5.0 48.0 HRVC-1280-2 110.8 363.0 116.4 88.3 1280 5.3 45.0 HRVC-1440-2 120.8 396.0 130.9 99.3 1440 6.0 40.0 HRVC-1560-2 130.6 429.0 141.8 107.6 1560 6.5 36.9 HRVC-1680-2 140.8 462.0 152.7 115.9 1680 7.0 34.3 HRVC-1920-2 161.0 528.0 174.5 132.4 1920 8.0 30.0 HRVC-2160-2 181 594 196.4 149.0 2160 9.0 26.7 HRVC-2400-2 201 660 218.2 165.5 2400 10.0 24.0 HRVC-2640-2 221.2 726 240.0 182.1 2640 11.0 21.8 HRVC-2880-2 241.4 792 261.8 198.6 2880 12.0 20.0 HRVC-3120-2 261.6 858 283.6 215.2 3120 13.0 18.5 HRVC-3360-2 281.6 924 305.5 231.7 3360 14.0 17.1 HRVC-3600-2 301.8 990 327.3 248.3 3600 15.0 16.0 Herein, 1 and 2 means the operation voltage, “1”=120V, “2”=240V

Learn More
Constant Wattage Heating Cable

  TXLP/2R Twin conductor underfloor heating cable widely used for thick concrete heating, soil heating and road snow melting, etc.

Learn More
explosion-proof temperature controller

Product Description: BWK Electric heating explosion-proof temperature controller Common voltage: 220V/380V Product classification: Electric heat tracing accessories The explosion-proof temperature controller for electric heat tracing is used to control the temperature of the heat tracing medium and serves as an accessory for electric heat tracing. Explosion proof power supply connection box used for connection of power cable and electric heating cable in explosion proof area. Generally fixed in the pipe. After matching with the electric heating system, it is suitable to use in the factory area and the two area explosive gas mixture T4 group field use. Explosion proof power supply connection box can be one-way output, and can be two-way output.

Learn More
Constant Wattage Heating Cable

Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure.

Learn More
floor heating system Accessories

  The steel strip and fixer of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline. Application   The steel strip and fixer of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline. The steel strip can be cut by 1.1 times the actual fixed length according to the diameter of the pipe. The front and back ends of the adjusting screw are respectively fixed in the small holes of the two ends, and the screw can be tightened. Self-regulating Heating Cable Steel Strapping of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline. The steel strip can be cut by 1.1 times the actual fixed length according to the diameter of the pipe. The front and back ends of the adjusting screw are respectively fixed in the small holes of the two ends, and the screw can be tightened.   We have two type of cable strapping, one for our T-cable(3.6mm), another for our I-cable(5.0mm)

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype

whatsapp