  • Brand:

    Huanrui
  • Power Ouput:

    10,17,25,31,40(W/M)
  • Max. Maintain Temperature:

    65℃
  • Max. Exposure Temperature:

    85℃
  • Min. Installation Temperature:

    -60℃
  • Rated Voltage:

    110V-120V/220V-240V
  • Max. Resistance of Braid:

    ≤18.2Ω/Km
  • Bus Wire Gauge:

    1.37mm²
  • Certifications:

    CE,EAC,EACEX,ATEX,IEx e IIC T6 Gb X,Ex tb IIIC T85°C Db X

  Constructed of a semi-conductive heater matrix extruded between parallel bus wires, a self-regulating cable adjusts its output to independently respond to ambient temperatures all along its length. As temperature increases, the heater's resistance increases, which lowers the output wattage. 

  Conversely, as the temperature decreases, the resistance decreases and the cable produces more heat. So thermostat is not necessary in some applications. It will never overheat or burnout even when overlapped. The cable can also be cut to any length. As the result, we got an energy efficient heating cable.

RSR Series

RSR-P: Tinned copper braid provides additional mechanical and ground protection.

RSR-PB: Flame retardant thermoplastic outer jacket protects against certain inorganic chemical solutions, it also protects against abrasion and impact damage.

RSR-PF: Fluoropolymer outer jacket is used for exposure to organic or corrosive working conditions.



The unique advantages of Huanrui self-regulating heating cable:

1. Improve the temperature resistance level: The temperature resistance level of the PTC semiconductor irradiation heating matrix can reach 100-110°C as needed to improve operational safety.

2. Reduce the starting current: Huanrui adopts double-layer co-extrusion technology, the starting current in the normal power range reaches <0.3A/M, and the ratio of starting current to steady-state current is less than 3 times.

3. Advanced insulation material: The insulation material is 100% matched with the PTC semiconductor irradiation heating matrix. In addition, it has excellent weather resistance, high temperature resistance, and insulation resistance of >2000MΩ, making it safer and more reliable.

4. New process: Huanrui adopts multi-layer co-extrusion technology. The insulation layer and PTC semiconductor irradiation heating matrix are extruded at the same time and completed in one go. The heating matrix and insulation are seamlessly integrated and cannot be peeled off, completely eliminating moisture and water when immersed, impurities cannot harm the core tape. Improve product service life.

Never overheat or burnout when overlapped. Cut to any length. Easy to install.




Application

RSR is ideally used for process temperature maintenance and frost protection of regular diameter pipelines, tanks, valves, flanges, roof & gutter de-icing and other applications of low temperature working conditions. It is suitable for non-hazardous area, and cable with fluoropolymer outer jacket can also be used in hazardous area and corrosive area.


Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
self regulating heating cable kit

RSR kit easily prevents the ice and snow from forming on roof and in gutter; keeps the house safe from ice snow dam.

Learn More
Constant Wattage Heating Cable

North America PHC twin conductor pipe heating cable.

Learn More
floor heating system Accessories

Product Description:Floor Heating membrane UM505 Material:polyethylene(PE)film top; polypropylene (PP) nonwoven bottom Roll Size:1mx20m,1mx10m,1mx5m Weight:1000g/sqm Thickness:5.6mm Film thick:0.45mm Wire cable diameter:3.6-4.2mm Installation Temperature:-10℃to 40℃, but limited by tile adhesive specification Storage Temperature:Max. 45℃ Melting:160℃ Steam Resistance:160m Equivalent air layer Air gap volume:2.8 litre/m2 Filling volume of the studs:2.3 litre/m2 Distance of the studs:4.0 mm Crack bridging:0.32mm Tensile Strength:73N/cm Waterpoof:yes Packing:wrapped in plastic film Color:Red, Orange, Yellow, Blue etc Estimation of power may achieve from different cable distribution: @64mm spacing 214W/m2 @96mm spacing 142W/m2 @128mm spacing 100W/m2 CAD Drawing:

Learn More
self regulating heating cable

PSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

Learn More
Constant Wattage Heating Cable

Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure.

Learn More
Weekly Programming Thermostat with LCD Screen

Weekly Programming Thermostat with LCD Screen.

Learn More
self regulating heating cable

XBR self-regulating heating cables provides the most versatility in heat trace designs and applications. This product has been used for over 100,000 meters in our company’s key partners, PetroChina, CNOOC,Sinopec,China Aerospace,Wanhua Chemical and other global Fortune 500 companies.

Learn More
Touch Screen Period Programming Thermostat

Touch Screen Period Programming Thermostat.

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype

whatsapp