Pipe Freeze Free Heating Cable SSR
Home / Pipe Freeze Free Heating Cable / Pipe Freeze Free Self-Regulating Heating Cable / Pipe Freeze Free Heating Cable SSR /

Chinese Manufacturer Wire Line Newest Pipe Antifreezing Heating Cable SSR

self regulating heating cable

Chinese Manufacturer Wire Line Newest Pipe Antifreezing Heating Cable SSR


SSR self-regulating heating cables provide the most versatility in heat trace designs and applications.


  • Brand:

    Huanrui
  • Power Ouput:

    34,45,60(W/M)
  • Max. Maintain Temperature:

    110℃
  • Max. Exposure Temperature:

    135℃
  • Min. Installation Temperature:

    -40℃
  • Rated Voltage:

    110V-120V/220V-240V
  • Max. Resistance of Braid:

    ≤18.2Ω/Km
  • Bus Wire Gauge:

    16AWG
  • Certifications:

    CE,EAC,EACEX,ATEX


  Constructed of a semi-conductive heater matrix extruded between parallel bus wires, a self-regulating cable adjusts its output to independently respond to ambient temperatures all along its length. As temperature increases, the heater's resistance increases, which lowers the output wattage. 

  Conversely, as the temperature decreases, the resistance decreases and the cable produces more heat. So thermostat is not necessary in some applications. It will never overheat or burnout even when overlapped. The cable can also be cut to any length. As the result, we got an energy efficient heating cable.


Product advantages

1.Self regulating heating cable :  

2.Low decrease in wattage

3.Long working life

4.Low starting current

5.High insulation resistance

6.High resistance to low and high temperature

7.Patented 3-layer co-extrusion technique

8.High stability in performance

9.Free of maintenance

10.Durable and strong structure

11.100% tested before delivery

12.Anti-UV




SSR Series

SSR-P: Tinned copper braid provides additional mechanical and ground protection. 

SSR-PB: Flame retardant thermoplastic outer jacket protects against certain inorganic chemical solutions, it also protects against abrasion and impact damage.

SSR-PF: Fluoropolymer outer jacket is used for exposure to organic or corrosive working conditions or vapor may exist.


Application

SSR is ideally used for process temperature maintenance and frost protection of large diameter pipelines, tanks, valves, flanges, and other industrial applications of high heat loss issues. It is suitable for non-hazardous area, and cable with fluoropolymer outer jacket can also be used in hazardous area and corrosive area.



Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
Wifi Thermostat

 Heating Thermostat User Manual Many thanks for your selection of our products and services, and also for your trust and support to us. Features Appearance (1) Standard total Size is 86*86mm (2) Touch buttons to make simple operation (3) The visible thickness above the wall is only 15mm86mm (4) hidden box and 60mm European box (5) Display size : 64*64mm (6) Color:white,black Functions (A) Including built-in sensor and external sensor (B) 0.5°C accuracy keeps temperature within the level you set. (C) Children lock to prevent misoperation by children (D) Data memory when power is off. (E) Holiday mode make you enjoy more comfortable temperature in holiday (F) The temperature of external sensor can be checked Product Specifications ☆ Power: 90-240Vac 50/60HZ ☆ Range of temperature display: 0~40°C ☆ Max. control accuracy: 0.5°C ☆ Probe sensor: NTC(10k)1% ☆ Contact capacity: 3A/250V(WW);16A/250V(WE) ☆ Output: Switch relay ☆ Limit temperature range: 0~70°C ☆ Insulating condition: Normal environment ☆ Default setting temperature range:5~35°C ☆ Size(mm):86*86*27 Before wiring and installation 1.Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2.Check the ratings given in the instructions and on the product to make sure the produce is suitable for your application. 3.Installer must be a trained experienced service technician. 4.After installation is complete.check out produce operation as provided in these instructions CAUTION Electrical shock or equipment Damage Hazard. or short equipment circuitry. Disconnect power supply before installation                                    Sensor fault display:please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop heating until the fault is eliminated Warranty: We offer the warranty of 18 months, from the sales day. The products of our company can have lifetime warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale service

Learn More
self regulating heating cable

RSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

Learn More
self regulating heating cable

RSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

Learn More
Constant Wattage Heating Cable

  HRSHTV heating cable is designed for both roof and gutter or ground applications. HRSHTV is a twin conductor heating cable for easy installation with zero EMF.

Learn More
self regulating heating cable

FSR kit easily prevents damage and leakage caused by frost and eliminates the inconvenience from iced water; as well as prevents the ice and snow from forming on roof and in gutter. FSR heating cable with a prefabricated plug for easier connection to AC power. Typical applications include roof & gutters, drains, water pipes, large diameter tanks, valves, flanges those will suffer from the damages caused by high heat loss.

Learn More
Constant Wattage Heating Cable

North America PHC twin conductor pipe heating cable.

Learn More
Constant Wattage Heating Cable

T-cable floor warming cable brings warm and comfortable feeling to people in cold season, using a proven technique which is energy-saving, safe and reliable.

Learn More
Constant Wattage Heating Cable

Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure.

Learn More
Top