Industrial Heating Cable RSR
Home / Industrial Heat Tracing / Industrial Self-Regulating Heating Cable / Industrial Heating Cable RSR /

65℃/85℃ Industrial Self-Regulating Heat Cable OEM Heating Trace Cable RSR

self regulating heating cable

65℃/85℃ Industrial Self-Regulating Heat Cable OEM Heating Trace Cable RSR

RSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

This product has been used for over 1000,000 meters in our company’s key partners, PetroChina, CNOOC,Sinopec,China Aerospace,Wanhua Chemical and other global Fortune 500 companies.

  • Brand:

    Huanrui
  • Power Ouput:

    10,17,25,31,40(W/M)
  • Max. Maintain Temperature:

    65℃
  • Max. Exposure Temperature:

    85℃
  • Min. Installation Temperature:

    -60℃
  • Rated Voltage:

    110V-120V/220V-240V
  • Max. Resistance of Braid:

    ≤18.2Ω/Km
  • Bus Wire Gauge:

    1.37mm²
  • Certifications:

    CE,EAC,EACEX,ATEX,IEx e IIC T6 Gb X,Ex tb IIIC T85°C Db X

  Constructed of a semi-conductive heater matrix extruded between parallel bus wires, a self-regulating cable adjusts its output to independently respond to ambient temperatures all along its length. As temperature increases, the heater's resistance increases, which lowers the output wattage. 

  Conversely, as the temperature decreases, the resistance decreases and the cable produces more heat. So thermostat is not necessary in some applications. It will never overheat or burnout even when overlapped. The cable can also be cut to any length. As the result, we got an energy efficient heating cable.



The unique advantages of Huanrui self-regulating heating cable:

1. Improve the temperature resistance level: The temperature resistance level of the PTC semiconductor irradiation heating matrix can reach 100-110°C as needed to improve operational safety.

2. Reduce the starting current: Huanrui adopts double-layer co-extrusion technology, the starting current in the normal power range reaches <0.3A/M, and the ratio of starting current to steady-state current is less than 3 times.

3. Advanced insulation material: The insulation material is 100% matched with the PTC semiconductor irradiation heating matrix. In addition, it has excellent weather resistance, high temperature resistance, and insulation resistance of >2000MΩ, making it safer and more reliable.

4. New process: Huanrui adopts multi-layer co-extrusion technology. The insulation layer and PTC semiconductor irradiation heating matrix are extruded at the same time and completed in one go. The heating matrix and insulation are seamlessly integrated and cannot be peeled off, completely eliminating moisture and water when immersed, impurities cannot harm the core tape. Improve product service life.

Never overheat or burnout when overlapped. Cut to any length. Easy to install.





RSR Series

RSR-P: Tinned copper braid provides additional mechanical and ground protection.

RSR-PB: Flame retardant thermoplastic outer jacket protects against certain inorganic chemical solutions, it also protects against abrasion and impact damage.

RSR-PF: Fluoropolymer outer jacket is used for exposure to organic or corrosive working conditions.


Application

RSR is ideally used for process temperature maintenance and frost protection of regular diameter pipelines, tanks, valves, flanges, roof & gutter de-icing and other applications of low temperature working conditions. It is suitable for non-hazardous area, and cable with fluoropolymer outer jacket can also be used in hazardous area and corrosive area.


Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
China BHD electric heating explosion-proof power supply junction box Manufacturer

Common voltage: 220V/380V Temperature resistance: 300 ℃ Product certification: 3C certification The BHD electric heat tracing explosion-proof power supply junction box is a single and bidirectional universal type, which can output the electric ribbon cable in one direction or in two directions. There are three wiring terminals inside the junction box, which can be used for connecting three-phase electric heating strips. When using single-phase, the middle wiring terminal is not used.

Learn More
Constant Wattage Heating Cable

  TXLP/2R Twin conductor underfloor heating cable widely used for thick concrete heating, soil heating and road snow melting, etc.

Learn More
Heat Cable Kit

HRHC roof and gutter de-icing cables help end costly ice damage by preventing ice dam formation and promoting the free flow of water through gutters and downspouts to ground level.

Learn More
China BHI electric heating explosion-proof two-way junction box Manufacturer

Common voltage: 220V/380V Product classification: Electric heat tracing accessories Product certification: 3C certification Explosion proof intermediate junction box (commonly known as two-way). It is mainly used for the connection between explosion-proof area electric heating strips and electric heating strips to increase the length of the electric heating strips, or for complex occasions such as using different power electric heating strips and triple pipes on the same pipeline. Its shell is made of PMC plastic.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications: •    Round-shape structure, flexible installation. •    About 3.6 mm diameter, convenient for installation. •    Twin conductor structure with one end cold lead for easy installation. •    Zero EMF. •    Can be used safely in wet conditions like bathroom. •    Quick and easy installation. •    Durable structure, long service life requiring no maintenance. •    15-year warranty for quality only, not including wrong installation and misuse.   Warranty: 15 years limited warranty against defect in material, design and workmanship. 120V Length Heating area  Total Power/W  (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-60-1 5.05 16.5 5.5 4.1 60 0.5 240.0 HRVC-120-1 10.1 33.0 10.9 8.3 120 1.0 120.0 HRVC-180-1 15.1 49.5 16.4 12.4 180 1.5 80.0 HRVC-240-1 20.1 66.0 21.8 16.6 240 2.0 60.0 HRVC-300-1 25.1 82.5 27.3 20.7 300 2.5 48.0 HRVC-360-1 30.2 99.0 32.7 24.8 360 3.0 40.0 HRVC-420-1 35.2 115.5 38.2 29.0 420 3.5 34.3 HRVC-480-1 40.2 132.0 43.6 33.1 480 4.0 30.0 HRVC-540-1 45.3 148.5 49.1 37.2 540 4.5 26.7 HRVC-600-1 50.3 165.0 54.5 41.4 600 5.0 24.0 HRVC-720-1 60.4 198.0 65.5 49.7 720 6.0 20.0 HRVC-840-1 70.4 231.0 76.4 57.9 840 7.0 17.1 HRVC-960-1 80.5 264.0 87.3 66.2 960 8.0 15.0 HRVC-1080-1 90.5 297.0 98.2 74.5 1080 9.0 13.3 HRVC-1200-1 100.5 330.0 109.1 82.8 1200 10.0 12.0 HRVC-1320-1 110.6 363.0 120.0 91.0 1320 11.0 10.9 HRVC-1440-1 120.7 396.0 130.9 99.3 1440 12.0 10.0 HRVC-1560-1 130.8 429.0 141.8 107.6 1560 13.0 9.2 HRVC-1680-1 140.8 462.0 152.7 115.9 1680 14.0 8.6 HRVC-1800-1 150.9 495.0 163.6 124.1 1800 15.0 8.0 240V Length Heating area   Total Power/W (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-120-2 10.1 33.0 10.9 8.3 120 0.5 480.0 HRVC-180-2 15.1 49.5 16.4 12.4 180 0.8 320.0 HRVC-240-2 20.2 66.0 21.8 16.6 240 1.0 240.0 HRVC-300-2 25.1 82.5 27.3 20.7 300 1.3 192.0 HRVC-360-2 30.2 99.0 32.7 24.8 360 1.5 160.0 HRVC-420-2 35.2 115.5 38.2 29.0 420 1.8 137.1 HRVC-480-2 40.2 132.0 43.6 33.1 480 2.0 120.0 HRVC-540-2 45.3 148.5 49.1 37.2 540 2.3 106.7 HRVC-600-2 50.2 165.0 54.5 41.4 600 2.5 96.0 HRVC-720-2 60.4 198.0 65.5 49.7 720 3.0 80.0 HRVC-840-2 70.4 231.0 76.4 57.9 840 3.5 68.6 HRVC-960-2 80.4 264.0 87.3 66.2 960 4.0 60.0 HRVC-1080-2 90.6 297.0 98.2 74.5 1080 4.5 53.3 HRVC-1200-2 100.6 330.0 109.1 82.8 1200 5.0 48.0 HRVC-1280-2 110.8 363.0 116.4 88.3 1280 5.3 45.0 HRVC-1440-2 120.8 396.0 130.9 99.3 1440 6.0 40.0 HRVC-1560-2 130.6 429.0 141.8 107.6 1560 6.5 36.9 HRVC-1680-2 140.8 462.0 152.7 115.9 1680 7.0 34.3 HRVC-1920-2 161.0 528.0 174.5 132.4 1920 8.0 30.0 HRVC-2160-2 181 594 196.4 149.0 2160 9.0 26.7 HRVC-2400-2 201 660 218.2 165.5 2400 10.0 24.0 HRVC-2640-2 221.2 726 240.0 182.1 2640 11.0 21.8 HRVC-2880-2 241.4 792 261.8 198.6 2880 12.0 20.0 HRVC-3120-2 261.6 858 283.6 215.2 3120 13.0 18.5 HRVC-3360-2 281.6 924 305.5 231.7 3360 14.0 17.1 HRVC-3600-2 301.8 990 327.3 248.3 3600 15.0 16.0 Herein, 1 and 2 means the operation voltage, “1”=120V, “2”=240V

Learn More
Electric heat tracing accessories

Common voltage: 220V/380V Product classification: Electric heat tracing accessories The explosion-proof distribution box (cabinet) for electric heat tracing is made of aluminum alloy, electrostatic spray plastic, and complies with the explosion-proof regulations of GB3836.2-2000. It is used for the distribution of electric heat tracing products in Class II, Zone 1, and Zone 2 explosion-proof areas. It has overload, single phase, and three-phase two categories, and outputs 1-12 circuits. There are two types of temperature control: fractional display temperature controller and BJW type temperature controller. Anhui huanrui electrical conduit with thermal control and monitoring system will be widely used in the fire pipes, pumps, valves, tank and tank container with heat, anti freezing and anti coagulation, and other heat tracing system. In addition, traffic, petroleum, chemical, electric power, medicine, machinery, food, shipping and other fields, can play a huge role. The real intelligent control can be realized with the current electric heat tracing system.

Learn More
China BHT electric heating explosion-proof three-way junction box Manufacturer

Common voltage: 220V/380V Product classification: Electric heat tracing accessories Product certification: 3C certification

Learn More
Constant Wattage Heating Mat

Electric Underfloor Heating Mat HRWT3.2. With twisted structure, the mat is flexible and easy to install.

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype