Industrial Heating Cable PSR
Home / Industrial Heat Tracing / Industrial Self-Regulating Heating Cable / Industrial Heating Cable PSR /

Hot Sell 220v Industry Insulation Pipe Roof Defrost Heating Tracing Cables

self regulating heating cable

Hot Sell 220v Industry Insulation Pipe Roof Defrost Heating Tracing Cables

PSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

  • Brand:

    Huanrui
  • Power Ouput:

    35,45,60(W/M)
  • Max. Maintain Temperature:

    85°C
  • Max. Exposure Temperature:

    135°C
  • Min. Installation Temperature:

    -40°C
  • Rated Voltage:

    110V-120V/220V-240V
  • Max. Resistance of Braid:

    ≤18.2Ω/Km
  • Bus Wire Gauge:

    16AWG
  • Certifications:

    CE,EAC,EACEX,ATEX

  Constructed of a semi-conductive heater matrix extruded between parallel bus wires, a self-regulating cable adjusts its output to independently respond to ambient temperatures all along its length. As temperature increases, the heater's resistance increases, which lowers the output wattage. 

  Conversely, as the temperature decreases, the resistance decreases and the cable produces more heat. So thermostat is not necessary in some applications. It will never overheat or burnout even when overlapped. The cable can also be cut to any length. As the result, we got an energy efficient heating cable. With optional outer jackets, the heating cable is resistant to watery and inorganic chemicals and protected against abrasion and impact damage.



Product advantages

1.Self regulating heating cable :  

2.Low decrease in wattage

3.Long working life

4.Low starting current

5.High insulation resistance

6.High resistance to low and high temperature

7.Patented 3-layer co-extrusion technique

8.High stability in performance

9.Free of maintenance

10.Durable and strong structure

11.100% tested before delivery

12.Anti-UV


PSR Series

PSR-P: Tinned copper braid provides additional mechanical and ground protection. 

PSR-PB: Flame retardant thermoplastic outer jacket protects against certain inorganic chemical solutions, it also protects against abrasion and impact damage.

PSR-PF: Fluoropolymer outer jacket is used for exposure to organic or corrosive working conditions or vapor may exist.


Application

PSR is designed for pipe heat trace in industrial applications. It is ideally used for process temperature maintenance and frost protection of large diameter pipelines, tanks, valves, flanges and other applications of high heat loss issues. It is suitable for non-hazardous area, and cable with fluoropolymer outer jacket can also be used in hazardous area and corrosive area.


Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
Constant Wattage Heating Cable

  T-cable underfloor heating cable is designed to be as thin as possible, diameter is only 3.6mm.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications • Residential indoor floor warming. • Workable in humid places such as bathroom. • Applicable for flooring material like concrete, ceramic tile, marble, wood. • Easy installation for indoor whole and partial warming systems for floor and wall warming. • 2.8mm in diameter; lower height, cost-saving. Part Number Length/ m OutputPower/W Resistance/ Q S-cable15-150 10 150 352.7 S-cable15-225 15 225 235.1 S-cable15-300 20 300 176.3 S-cable15-375 25 375 141.1 S-cable15-450 30 450 117.6 S-cable15-525 35 525 100.8 S-cable15-600 40 600 88.2 S-cable15-750 50 750 70.5 S-cable15-900 60 900 58.8 S-cable15-1050 70 1050 50.4 S-cable15-1200 80 1200 44.1 S-cable15-1350 90 1350 39.2 S-cable15-1500 100 1500 35.3 S-cable15-1800 120 1800 29.4 Part Number Length/ m Power Output/W Resistance/Q S-cable10-100 10 100 529.0 S-cable10-150 15 150 352.7 S-cable10-200 20 200 264.5 S-cable10-250 25 250 211.6 S-cable10-300 30 300 176.3 S-cable10-350 35 350 151.1 S-cable10-400 40 400 132.3 S-cable10-450 45 450 117.6 S-cable10-500 50 500 105.8 S-cable10-600 60 600 88.2 S-cable10-700 70 700 75.6 S-cable10-800 80 800 66.1 S-cable10-900 90 900 58.8 S-cable10-1000 100 1000 52.9 S-cable10-1200 120 1200 44.1

Learn More
Constant Wattage Heating Cable

Electric Underfloor Heating Cable HRWT3.2. With twisted structure, the cable is flexible and easy to install.

Learn More
Constant Wattage Heating Mat

Electric Underfloor Heating Mat HRWT3.2. With twisted structure, the mat is flexible and easy to install.

Learn More
heat cable

FSR kit easily prevents damage and leakage caused by frost and eliminates the inconvenience from iced water; as well as prevents the ice and snow from forming on roof and in gutter. FSR heating cable with a prefabricated plug for easier connection to AC power. Typical applications include roof & gutters, drains, water pipes, large diameter tanks, valves, flanges those will suffer from the damages caused by high heat loss.

Learn More
Constant Wattage Heating Mat

HRTK underfloor heating mat uses a twin conductor heating cable for easy installation and mat with zero EMF, designed for installation into thin adhesive beds, leveling compounds or thin screed beds beneath tiled and wooden floor finish.

Learn More
Constant Wattage Heating Cable

Electric Underfloor Heating Cable HRVP3.65. With twisted structure, the cable is flexible and easy to install.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance 9.Anti-UV Features and applications • 5.5mm diameter. • Twin conductor; with plug, ready for use. • Zero EMF. • Can be used in humid places. • Multi-layer XLPE material, the mechanical strength of the product can reach class. M2, and will not be deformed in short-term exposure up to 150°C. • This product is mainly used for concrete curing.

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype

whatsapp