Snow Melting Heating Cable HRSHTV
Home / Snow Melting Heating Cable And Mat / Snow Melting Constant Wattage Heating Cable And Mat / Snow Melting Heating Cable HRSHTV /

Ramp Sidewalk Square Asphalt Road And Flyover Snow Heating Cable

Constant Wattage Heating Cable

Ramp Sidewalk Square Asphalt Road And Flyover Snow Heating Cable

  HRSHTV heating cable is designed for both roof and gutter or ground applications. HRSHTV is a twin conductor heating cable for easy installation with zero EMF.

  • Brand:

    Huanrui
  • Power Ouput:

    20,30W/M
  • Rated Voltage:

    230V
  • Outer Jacket:

    PVC
  • Outer dimensions:

    6.0-6.5mm
  • Insulation material:

    XLPE ( Cross-linked PE)
  • Cable structure:

    Twin conductor
  • Shield:

    Aluminum-plastic tape and tinned copper wires
  • Conductor:

    Solid heating core
  • Connector:

    Out splice
  • Resistance tolerance:

    +10%/-5%
  • Certifications:

    CE

  HRSHTV is a fully screened twin conductor cable with a tough black UV protected PVC outer sheath, to install in outdoor applications such as roof and gutter or ground applications. Its round profile makes it simple to install in outdoor applications such as roof and gutter or ground applications.



Product advantages

1.Durable and strong structure

2.High water-proofness.  IP68

3.Long working life

4.25years warranty

5.Small size ,no increase in floor thickness

6.100% screened with Zero EMF

7.100% tested before delivery

8.Free of maintenance

9.Anti-UV




Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
China Power Junction Box BHD-F Manufacturer

Shell material: engineering plastic Current ≤40A. Thread specification:NPT; M40*1.5, M32*1.5, M25*1.5 M20*1.5, M12*1.5 Shell size (mm): 120*120*100; 130*130*120; 220*130*120 Scope of use: Self-limiting temperature heating tape, constant power heating tape, connection components of series constant power power cords and heating tapes.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications • Residential indoor floor warming. • Workable in humid places such as bathroom. • Applicable for flooring material like concrete, ceramic tile, marble, wood. • Easy installation for indoor whole and partial warming systems for floor and wall warming. • 2.8mm in diameter; lower height, cost-saving. Part Number Length/ m OutputPower/W Resistance/ Q S-cable15-150 10 150 352.7 S-cable15-225 15 225 235.1 S-cable15-300 20 300 176.3 S-cable15-375 25 375 141.1 S-cable15-450 30 450 117.6 S-cable15-525 35 525 100.8 S-cable15-600 40 600 88.2 S-cable15-750 50 750 70.5 S-cable15-900 60 900 58.8 S-cable15-1050 70 1050 50.4 S-cable15-1200 80 1200 44.1 S-cable15-1350 90 1350 39.2 S-cable15-1500 100 1500 35.3 S-cable15-1800 120 1800 29.4 Part Number Length/ m Power Output/W Resistance/Q S-cable10-100 10 100 529.0 S-cable10-150 15 150 352.7 S-cable10-200 20 200 264.5 S-cable10-250 25 250 211.6 S-cable10-300 30 300 176.3 S-cable10-350 35 350 151.1 S-cable10-400 40 400 132.3 S-cable10-450 45 450 117.6 S-cable10-500 50 500 105.8 S-cable10-600 60 600 88.2 S-cable10-700 70 700 75.6 S-cable10-800 80 800 66.1 S-cable10-900 90 900 58.8 S-cable10-1000 100 1000 52.9 S-cable10-1200 120 1200 44.1

Learn More
Heat cable

FSR self-regulating heating cable is constructed of a semi-conductive heater matrix extruded between parallel bus wires, a self-regulating cable adjusts its output to independently respond to ambient temperatures all along its length.

Learn More
China BHD electric heating explosion-proof power supply junction box Manufacturer

Common voltage: 220V/380V Temperature resistance: 300 ℃ Product certification: 3C certification The BHD electric heat tracing explosion-proof power supply junction box is a single and bidirectional universal type, which can output the electric ribbon cable in one direction or in two directions. There are three wiring terminals inside the junction box, which can be used for connecting three-phase electric heating strips. When using single-phase, the middle wiring terminal is not used.

Learn More
heating cable

RSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

Learn More
self regulating heating cable

FSR self-regulating heating cable is constructed of a semi-conductive heater matrix extruded between parallel bus wires, a self-regulating cable adjusts its output to independently respond to ambient temperatures all along its length. This product has been used for over 1000,000 meters in our company’s key partners, PetroChina, CNOOC,Sinopec,China Aerospace,Wanhua Chemical and other global Fortune 500 companies.

Learn More
Constant Wattage Heating Mat

HRDVCM underfloor heating mat uses a twin conductor heating cable for easy installation, and mat is designed for installation into thin adhesive beds, leveling compounds or thin screed beds beneath tiled and wooden floor.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications: •    Round-shape structure, flexible installation. •    About 3.6 mm diameter, convenient for installation. •    Twin conductor structure with one end cold lead for easy installation. •    Zero EMF. •    Can be used safely in wet conditions like bathroom. •    Quick and easy installation. •    Durable structure, long service life requiring no maintenance. •    15-year warranty for quality only, not including wrong installation and misuse.   Warranty: 15 years limited warranty against defect in material, design and workmanship. 120V Length Heating area  Total Power/W  (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-60-1 5.05 16.5 5.5 4.1 60 0.5 240.0 HRVC-120-1 10.1 33.0 10.9 8.3 120 1.0 120.0 HRVC-180-1 15.1 49.5 16.4 12.4 180 1.5 80.0 HRVC-240-1 20.1 66.0 21.8 16.6 240 2.0 60.0 HRVC-300-1 25.1 82.5 27.3 20.7 300 2.5 48.0 HRVC-360-1 30.2 99.0 32.7 24.8 360 3.0 40.0 HRVC-420-1 35.2 115.5 38.2 29.0 420 3.5 34.3 HRVC-480-1 40.2 132.0 43.6 33.1 480 4.0 30.0 HRVC-540-1 45.3 148.5 49.1 37.2 540 4.5 26.7 HRVC-600-1 50.3 165.0 54.5 41.4 600 5.0 24.0 HRVC-720-1 60.4 198.0 65.5 49.7 720 6.0 20.0 HRVC-840-1 70.4 231.0 76.4 57.9 840 7.0 17.1 HRVC-960-1 80.5 264.0 87.3 66.2 960 8.0 15.0 HRVC-1080-1 90.5 297.0 98.2 74.5 1080 9.0 13.3 HRVC-1200-1 100.5 330.0 109.1 82.8 1200 10.0 12.0 HRVC-1320-1 110.6 363.0 120.0 91.0 1320 11.0 10.9 HRVC-1440-1 120.7 396.0 130.9 99.3 1440 12.0 10.0 HRVC-1560-1 130.8 429.0 141.8 107.6 1560 13.0 9.2 HRVC-1680-1 140.8 462.0 152.7 115.9 1680 14.0 8.6 HRVC-1800-1 150.9 495.0 163.6 124.1 1800 15.0 8.0 240V Length Heating area   Total Power/W (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-120-2 10.1 33.0 10.9 8.3 120 0.5 480.0 HRVC-180-2 15.1 49.5 16.4 12.4 180 0.8 320.0 HRVC-240-2 20.2 66.0 21.8 16.6 240 1.0 240.0 HRVC-300-2 25.1 82.5 27.3 20.7 300 1.3 192.0 HRVC-360-2 30.2 99.0 32.7 24.8 360 1.5 160.0 HRVC-420-2 35.2 115.5 38.2 29.0 420 1.8 137.1 HRVC-480-2 40.2 132.0 43.6 33.1 480 2.0 120.0 HRVC-540-2 45.3 148.5 49.1 37.2 540 2.3 106.7 HRVC-600-2 50.2 165.0 54.5 41.4 600 2.5 96.0 HRVC-720-2 60.4 198.0 65.5 49.7 720 3.0 80.0 HRVC-840-2 70.4 231.0 76.4 57.9 840 3.5 68.6 HRVC-960-2 80.4 264.0 87.3 66.2 960 4.0 60.0 HRVC-1080-2 90.6 297.0 98.2 74.5 1080 4.5 53.3 HRVC-1200-2 100.6 330.0 109.1 82.8 1200 5.0 48.0 HRVC-1280-2 110.8 363.0 116.4 88.3 1280 5.3 45.0 HRVC-1440-2 120.8 396.0 130.9 99.3 1440 6.0 40.0 HRVC-1560-2 130.6 429.0 141.8 107.6 1560 6.5 36.9 HRVC-1680-2 140.8 462.0 152.7 115.9 1680 7.0 34.3 HRVC-1920-2 161.0 528.0 174.5 132.4 1920 8.0 30.0 HRVC-2160-2 181 594 196.4 149.0 2160 9.0 26.7 HRVC-2400-2 201 660 218.2 165.5 2400 10.0 24.0 HRVC-2640-2 221.2 726 240.0 182.1 2640 11.0 21.8 HRVC-2880-2 241.4 792 261.8 198.6 2880 12.0 20.0 HRVC-3120-2 261.6 858 283.6 215.2 3120 13.0 18.5 HRVC-3360-2 281.6 924 305.5 231.7 3360 14.0 17.1 HRVC-3600-2 301.8 990 327.3 248.3 3600 15.0 16.0 Herein, 1 and 2 means the operation voltage, “1”=120V, “2”=240V

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype