Pipe Antifreeze Heating Cable PHC
Home / Pipe Antifreeze Heating Cable / Pipe Antifreeze Constant Wattage Heating Cable / Pipe Antifreeze Heating Cable PHC /

Pipe Freeze Electric Constant Wattage Heating Cable PHC

Constant Wattage Heating Cable

Pipe Freeze Electric Constant Wattage Heating Cable PHC

PHC twin conductor pipe heating cable.

  • Brand:

    Huanrui
  • Power Ouput:

    10,12,15W/M
  • Min. Installation Temperature:

    -10℃
  • Rated Voltage:

    230V
  • Applicable areas :

    Europe
  • Application:

    Residential water pipe antifreeze
  • Min.bending radius:

    6D
  • Certifications:

    CE,EAC

Product advantages

1.Durable and strong structure

2.High water-proofness.  IP68

3.Long working life

4.25years warranty

5.Small size ,no increase in floor thickness

6.100% screened with Zero EMF

7.100% tested before delivery

8.Free of maintenance

9.Anti-UV

10. High-end automation equipment manufacturing

11.Complete product range

12.Global certification



Features and applications

• Pre-assembled with thermostat, intelligently controlled, energy-saving, users do not need to worry about the operation.

• Used to prevent water pipes from freezing, available in a minimum room temperature of -40°C.

•Pre-assembled product, easy to install and use.

•Pre-assembled with power plug, ready for use. 

•Can be used for plastic as well as for metal pipes.


Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
Constant Wattage Heating Cable

North America PHC twin conductor pipe heating cable.

Learn More
floor heating system Accessories

Product Description:Floor Heating membrane UM505 Material:polyethylene(PE)film top; polypropylene (PP) nonwoven bottom Roll Size:1mx20m,1mx10m,1mx5m Weight:1000g/sqm Thickness:5.6mm Film thick:0.45mm Wire cable diameter:3.6-4.2mm Installation Temperature:-10℃to 40℃, but limited by tile adhesive specification Storage Temperature:Max. 45℃ Melting:160℃ Steam Resistance:160m Equivalent air layer Air gap volume:2.8 litre/m2 Filling volume of the studs:2.3 litre/m2 Distance of the studs:4.0 mm Crack bridging:0.32mm Tensile Strength:73N/cm Waterpoof:yes Packing:wrapped in plastic film Color:Red, Orange, Yellow, Blue etc Estimation of power may achieve from different cable distribution: @64mm spacing 214W/m2 @96mm spacing 142W/m2 @128mm spacing 100W/m2 CAD Drawing:

Learn More
Constant Wattage Heating Cable

  Residential indoor electric underfloor heating cable.

Learn More
self regulating heating cable

MSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

Learn More
Constant Wattage Heating Cable

The HRDVT is a cable designed to prevent snow and ice accumulation around the home or facility, such as driveway, walkways and stairs and so on.

Learn More
China AH electric heating explosion-proof power supply junction box Manufacturer

Common voltage: 220V/380V Product classification: Electric heat tracing accessories Product certification: explosion-proof certification AH explosion-proof power junction box is suitable for environments with temperature groups T1~T6; Suitable for explosive hazardous environments such as oil extraction, storage, chemical, pharmaceutical, textile, printing and dyeing, military, and military facilities.

Learn More
Wifi Thermostat

 Heating Thermostat User Manual Many thanks for your selection of our products and services, and also for your trust and support to us. Features Appearance (1) Standard total Size is 86*86mm (2) Touch buttons to make simple operation (3) The visible thickness above the wall is only 15mm86mm (4) hidden box and 60mm European box (5) Display size : 64*64mm (6) Color:white,black Functions (A) Including built-in sensor and external sensor (B) 0.5°C accuracy keeps temperature within the level you set. (C) Children lock to prevent misoperation by children (D) Data memory when power is off. (E) Holiday mode make you enjoy more comfortable temperature in holiday (F) The temperature of external sensor can be checked Product Specifications ☆ Power: 90-240Vac 50/60HZ ☆ Range of temperature display: 0~40°C ☆ Max. control accuracy: 0.5°C ☆ Probe sensor: NTC(10k)1% ☆ Contact capacity: 3A/250V(WW);16A/250V(WE) ☆ Output: Switch relay ☆ Limit temperature range: 0~70°C ☆ Insulating condition: Normal environment ☆ Default setting temperature range:5~35°C ☆ Size(mm):86*86*27 Before wiring and installation 1.Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2.Check the ratings given in the instructions and on the product to make sure the produce is suitable for your application. 3.Installer must be a trained experienced service technician. 4.After installation is complete.check out produce operation as provided in these instructions CAUTION Electrical shock or equipment Damage Hazard. or short equipment circuitry. Disconnect power supply before installation                                    Sensor fault display:please choose correct working way of built-in and external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2” will be displayed on the screen. Thermostat will stop heating until the fault is eliminated Warranty: We offer the warranty of 18 months, from the sales day. The products of our company can have lifetime warranty ,if it is not the quality problems, or beyond the warranty period, we will charge for the after-sale service

Learn More
Constant Wattage Heating Cable

HRSHTV heating cable is designed for both roof and gutter or ground applications. HRSHTV is a twin conductor heating cable for easy installation with zero EMF.

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype

whatsapp