Industrial Heating Cable RDP
Home / Industrial Heat Tracing / Industrial Constant Wattage Heating Cable / Industrial Heating Cable RDP /

Parallel Resistance Constant Wattage Heating Cable For Industrial And Natural Gas Pipeline

Constant Wattage Heating Cable

Parallel Resistance Constant Wattage Heating Cable For Industrial And Natural Gas Pipeline

Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure.

  • Brand:

    Huanrui
  • Max. Exposure Temperature:

    205°C
  • Min. Installation Temperature:

    -60℃
  • Rated Voltage:

    220V
  • Bus Wire Gauge:

    2.0mm² & 2.5mm²
  • Dielectric strength:

    2000V 50Hz/1min
  • Outer dimensions:

    6.3x9.5mm
  • Insulation resistance:

    ≥20M Ohm
  • Insulation material:

    FEP
  • Protection Class:

    IP54
  • Certifications:

    CE,EAC,EACEX,ATEX,IEx e IIC T3 Gb X,Ex tb IIIC T200°C Db X

  This type provides an economical alternative to self-regulating heating cable but requires more skill for installation and more advanced control and monitor systems. Constant wattage heating cables can provide process temperature maintenance up to 150°C and can withstand exposure temperatures up to 205°C with power on.



Product advantages

1.Durable and strong structure

2.High water-proofness.  IP68

3.Long working life

4.25years warranty

5.Small size ,no increase in floor thickness

6.100% screened with Zero EMF

7.100% tested before delivery

8.Free of maintenance

9.Anti-UV

10. High-end automation equipment manufacturing

11.Complete product range

12.Global certification



Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications: •    Round-shape structure, flexible installation. •    About 3.6 mm diameter, convenient for installation. •    Twin conductor structure with one end cold lead for easy installation. •    Zero EMF. •    Can be used safely in wet conditions like bathroom. •    Quick and easy installation. •    Durable structure, long service life requiring no maintenance. •    15-year warranty for quality only, not including wrong installation and misuse.   Warranty: 15 years limited warranty against defect in material, design and workmanship. 120V Length Heating area  Total Power/W  (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-60-1 5.05 16.5 5.5 4.1 60 0.5 240.0 HRVC-120-1 10.1 33.0 10.9 8.3 120 1.0 120.0 HRVC-180-1 15.1 49.5 16.4 12.4 180 1.5 80.0 HRVC-240-1 20.1 66.0 21.8 16.6 240 2.0 60.0 HRVC-300-1 25.1 82.5 27.3 20.7 300 2.5 48.0 HRVC-360-1 30.2 99.0 32.7 24.8 360 3.0 40.0 HRVC-420-1 35.2 115.5 38.2 29.0 420 3.5 34.3 HRVC-480-1 40.2 132.0 43.6 33.1 480 4.0 30.0 HRVC-540-1 45.3 148.5 49.1 37.2 540 4.5 26.7 HRVC-600-1 50.3 165.0 54.5 41.4 600 5.0 24.0 HRVC-720-1 60.4 198.0 65.5 49.7 720 6.0 20.0 HRVC-840-1 70.4 231.0 76.4 57.9 840 7.0 17.1 HRVC-960-1 80.5 264.0 87.3 66.2 960 8.0 15.0 HRVC-1080-1 90.5 297.0 98.2 74.5 1080 9.0 13.3 HRVC-1200-1 100.5 330.0 109.1 82.8 1200 10.0 12.0 HRVC-1320-1 110.6 363.0 120.0 91.0 1320 11.0 10.9 HRVC-1440-1 120.7 396.0 130.9 99.3 1440 12.0 10.0 HRVC-1560-1 130.8 429.0 141.8 107.6 1560 13.0 9.2 HRVC-1680-1 140.8 462.0 152.7 115.9 1680 14.0 8.6 HRVC-1800-1 150.9 495.0 163.6 124.1 1800 15.0 8.0 240V Length Heating area   Total Power/W (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-120-2 10.1 33.0 10.9 8.3 120 0.5 480.0 HRVC-180-2 15.1 49.5 16.4 12.4 180 0.8 320.0 HRVC-240-2 20.2 66.0 21.8 16.6 240 1.0 240.0 HRVC-300-2 25.1 82.5 27.3 20.7 300 1.3 192.0 HRVC-360-2 30.2 99.0 32.7 24.8 360 1.5 160.0 HRVC-420-2 35.2 115.5 38.2 29.0 420 1.8 137.1 HRVC-480-2 40.2 132.0 43.6 33.1 480 2.0 120.0 HRVC-540-2 45.3 148.5 49.1 37.2 540 2.3 106.7 HRVC-600-2 50.2 165.0 54.5 41.4 600 2.5 96.0 HRVC-720-2 60.4 198.0 65.5 49.7 720 3.0 80.0 HRVC-840-2 70.4 231.0 76.4 57.9 840 3.5 68.6 HRVC-960-2 80.4 264.0 87.3 66.2 960 4.0 60.0 HRVC-1080-2 90.6 297.0 98.2 74.5 1080 4.5 53.3 HRVC-1200-2 100.6 330.0 109.1 82.8 1200 5.0 48.0 HRVC-1280-2 110.8 363.0 116.4 88.3 1280 5.3 45.0 HRVC-1440-2 120.8 396.0 130.9 99.3 1440 6.0 40.0 HRVC-1560-2 130.6 429.0 141.8 107.6 1560 6.5 36.9 HRVC-1680-2 140.8 462.0 152.7 115.9 1680 7.0 34.3 HRVC-1920-2 161.0 528.0 174.5 132.4 1920 8.0 30.0 HRVC-2160-2 181 594 196.4 149.0 2160 9.0 26.7 HRVC-2400-2 201 660 218.2 165.5 2400 10.0 24.0 HRVC-2640-2 221.2 726 240.0 182.1 2640 11.0 21.8 HRVC-2880-2 241.4 792 261.8 198.6 2880 12.0 20.0 HRVC-3120-2 261.6 858 283.6 215.2 3120 13.0 18.5 HRVC-3360-2 281.6 924 305.5 231.7 3360 14.0 17.1 HRVC-3600-2 301.8 990 327.3 248.3 3600 15.0 16.0 Herein, 1 and 2 means the operation voltage, “1”=120V, “2”=240V

Learn More
floor heating system Accessories

Product Description:Floor Heating membrane UM505 Material:polyethylene(PE)film top; polypropylene (PP) nonwoven bottom Roll Size:1mx20m,1mx10m,1mx5m Weight:1000g/sqm Thickness:5.6mm Film thick:0.45mm Wire cable diameter:3.6-4.2mm Installation Temperature:-10℃to 40℃, but limited by tile adhesive specification Storage Temperature:Max. 45℃ Melting:160℃ Steam Resistance:160m Equivalent air layer Air gap volume:2.8 litre/m2 Filling volume of the studs:2.3 litre/m2 Distance of the studs:4.0 mm Crack bridging:0.32mm Tensile Strength:73N/cm Waterpoof:yes Packing:wrapped in plastic film Color:Red, Orange, Yellow, Blue etc Estimation of power may achieve from different cable distribution: @64mm spacing 214W/m2 @96mm spacing 142W/m2 @128mm spacing 100W/m2 CAD Drawing:

Learn More
Constant Wattage Heating Cable

HRHC roof and gutter de-icing cables help end costly ice damage by preventing ice dam formation and promoting the free flow of water through gutters and downspouts to ground level.

Learn More
Heat Cable Kit

HRHC roof and gutter de-icing cables help end costly ice damage by preventing ice dam formation and promoting the free flow of water through gutters and downspouts to ground level.

Learn More
floor heating system Accessories

  The steel strip and fixer of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline.   It is for underfloor heating cable, make installation easier. Application   The steel strip and fixer of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline. The steel strip can be cut by 1.1 times the actual fixed length according to the diameter of the pipe. The front and back ends of the adjusting screw are respectively fixed in the small holes of the two ends, and the screw can be tightened. Self-regulating Heating Cable Steel Strapping of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline. The steel strip can be cut by 1.1 times the actual fixed length according to the diameter of the pipe. The front and back ends of the adjusting screw are respectively fixed in the small holes of the two ends, and the screw can be tightened.   We have two type of cable strapping, one for our T-cable(3.6mm), another for our I-cable(5.0mm)

Learn More
China Electric heat tracing aluminum foil tape Manufacturer

The main function of electric heating aluminum tape is to fix the electric heating strip and increase the heat dissipation surface of the electric heating strip. Aluminum tape is coated with a special adhesive layer on the aluminum foil tape. It is used for heating the temperature control device and the temperature sensing package of the temperature controller is convenient to install, and the main function is to fix the electric heating belt and increase the radiating surface of the electric heating belt.

Learn More
Constant Wattage Heating Cable

North America PHC twin conductor pipe heating cable.

Learn More
Constant Wattage Heating Mat

  T-mat underfloor heating mat uses a twin conductor heating cable for easy installation, and this mat is with zero EMF, designed for installation into thin adhesive beds, leveling compounds or thin screed beds beneath tiled and wooden floor.

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype

whatsapp