Roof & Gutter De-icing Heating Cable HM-cable
Home / Roof & Gutter De-icing Heating Cable / Roof & Gutter De-icing Constant Wattage Heating Cable / Roof & Gutter De-icing Heating Cable HM-cable /

Twin Conductor Heating Cable 230V for Roof Gutter Snow Melt

Constant Wattage Heating Cable

Twin Conductor Heating Cable 230V for Roof Gutter Snow Melt

The HM-cable is an electric heating cable designed to prevent snow and ice accumulation around the home or facility, such as driveway, walkway, stairs and so on.
  • Brand:

    Huanrui
  • Power Ouput:

    30W/M
  • Min. Installation Temperature:

    5°C
  • Rated Voltage:

    230V,400V
  • Outer Jacket:

    PVC
  • Outer dimensions:

    6.5mm
  • Insulation material:

    Fluoropolymer and XLPE
  • Cable structure:

    Twin conductor
  • Heating element length:

    10m to 120m
  • Bending radius:

    38mm
  • Jacket optional:

    XLPO for HM-cable(R)
  • Shield:

    Aluminum-plastic tape and tinned copper wires
  • Max. rated temperature:

    105°C
  • Cold lead:

    6m length
  • Certifications:

    CE

  The HM-cable is an electrically heated cable designed to prevent snow and ice accumulation around the home or facility, such as driveway, walkways and stairs and so on.

  In winter; when the accumulated snow on walkways, parking garage, loading ramps, stairways and other areas, it will bring problem to people's life. Electric snow melting systems can keep walkways, parking garage, loading ramps, stairways and other areas free of snow and ice to help prevent slip hazards. Electric snow melting systems provide surface snow melting and anti-icing for concrete surfaces and pavers.

  

Product advantages

1.Durable and strong structure

2.High water-proofness.  IP68

3.Long working life

4.25years warranty

5.Small size ,no increase in floor thickness

6.100% screened with Zero EMF

7.100% tested before delivery

8.Free of maintenance

9.Anti-UV

10. High-end automation equipment manufacturing

11.Complete product range

12.Global certification

Features

• Single point connection

• Robust, efficient, and safe

• Easy and flexible installation

• 10-year limited warranty against manufacturing defects

• Two conductors 

• Emits zero EMF (electromagnetic fields)

• Durable structure


Applications

  Installation of the HM-cable snow melting system provides a permanent solution to the problems caused by cold weather when snow and ice accumulation. It can be used both outdoor and indoor environment.



Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

New Products

Related Products
Constant Wattage Heating Cable

l-cable underfloor heating cable is designed for new buildings applications or any other circumstances where screed is going to be laid, l-cable is a twin conductor heating cable for easy installation with zero EMF.

Learn More
Constant Wattage Heating Cable

Electric Underfloor Heating Cable HRWT3.2. With twisted structure, the cable is flexible and easy to install.

Learn More
Constant Wattage Heating Cable

Parallel constant wattage heating cable can be used for pipe and equipment freeze protection and process temperature maintenance requiring high power output or high temperature exposure.

Learn More
Electric heat tracing accessories

Common voltage: 220V/380V Product classification: Electric heat tracing accessories The explosion-proof distribution box (cabinet) for electric heat tracing is made of aluminum alloy, electrostatic spray plastic, and complies with the explosion-proof regulations of GB3836.2-2000. It is used for the distribution of electric heat tracing products in Class II, Zone 1, and Zone 2 explosion-proof areas. It has overload, single phase, and three-phase two categories, and outputs 1-12 circuits. There are two types of temperature control: fractional display temperature controller and BJW type temperature controller. Anhui huanrui electrical conduit with thermal control and monitoring system will be widely used in the fire pipes, pumps, valves, tank and tank container with heat, anti freezing and anti coagulation, and other heat tracing system. In addition, traffic, petroleum, chemical, electric power, medicine, machinery, food, shipping and other fields, can play a huge role. The real intelligent control can be realized with the current electric heat tracing system.

Learn More
Constant Wattage Heating Cable

The HRTCPR is an electrically heated cable designed to prevent snow and ice accumulation around the home or facility, such as driveway, walkways and stairs and so on.

Learn More
Constant Wattage Heating Mat

S-mat underfloor heating mat is designed to be as thin as possible and 100% screened. The cable is designed for installation into thin adhesive beds, leveling compounds or thin screed beds beneath tiled and wooden floor.

Learn More
self regulating heating cable

MSR self-regulating heating cables provide the most versatility in heat trace designs and applications.

Learn More
Constant Wattage Heating Cable

Product advantages 1.Durable and strong structure 2.High water-proofness.  IP68 3.Long working life 4.25years warranty 5.Small size ,no increase in floor thickness 6.100% screened with Zero EMF 7.100% tested before delivery 8.Free of maintenance Features and applications: •    Round-shape structure, flexible installation. •    About 3.6 mm diameter, convenient for installation. •    Twin conductor structure with one end cold lead for easy installation. •    Zero EMF. •    Can be used safely in wet conditions like bathroom. •    Quick and easy installation. •    Durable structure, long service life requiring no maintenance. •    15-year warranty for quality only, not including wrong installation and misuse.   Warranty: 15 years limited warranty against defect in material, design and workmanship. 120V Length Heating area  Total Power/W  (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-60-1 5.05 16.5 5.5 4.1 60 0.5 240.0 HRVC-120-1 10.1 33.0 10.9 8.3 120 1.0 120.0 HRVC-180-1 15.1 49.5 16.4 12.4 180 1.5 80.0 HRVC-240-1 20.1 66.0 21.8 16.6 240 2.0 60.0 HRVC-300-1 25.1 82.5 27.3 20.7 300 2.5 48.0 HRVC-360-1 30.2 99.0 32.7 24.8 360 3.0 40.0 HRVC-420-1 35.2 115.5 38.2 29.0 420 3.5 34.3 HRVC-480-1 40.2 132.0 43.6 33.1 480 4.0 30.0 HRVC-540-1 45.3 148.5 49.1 37.2 540 4.5 26.7 HRVC-600-1 50.3 165.0 54.5 41.4 600 5.0 24.0 HRVC-720-1 60.4 198.0 65.5 49.7 720 6.0 20.0 HRVC-840-1 70.4 231.0 76.4 57.9 840 7.0 17.1 HRVC-960-1 80.5 264.0 87.3 66.2 960 8.0 15.0 HRVC-1080-1 90.5 297.0 98.2 74.5 1080 9.0 13.3 HRVC-1200-1 100.5 330.0 109.1 82.8 1200 10.0 12.0 HRVC-1320-1 110.6 363.0 120.0 91.0 1320 11.0 10.9 HRVC-1440-1 120.7 396.0 130.9 99.3 1440 12.0 10.0 HRVC-1560-1 130.8 429.0 141.8 107.6 1560 13.0 9.2 HRVC-1680-1 140.8 462.0 152.7 115.9 1680 14.0 8.6 HRVC-1800-1 150.9 495.0 163.6 124.1 1800 15.0 8.0 240V Length Heating area   Total Power/W (3.65W/ft) Current/Amps Resistance Ω/m Part Number m ft 11W/ft² 14.5W/ft² HRVC-120-2 10.1 33.0 10.9 8.3 120 0.5 480.0 HRVC-180-2 15.1 49.5 16.4 12.4 180 0.8 320.0 HRVC-240-2 20.2 66.0 21.8 16.6 240 1.0 240.0 HRVC-300-2 25.1 82.5 27.3 20.7 300 1.3 192.0 HRVC-360-2 30.2 99.0 32.7 24.8 360 1.5 160.0 HRVC-420-2 35.2 115.5 38.2 29.0 420 1.8 137.1 HRVC-480-2 40.2 132.0 43.6 33.1 480 2.0 120.0 HRVC-540-2 45.3 148.5 49.1 37.2 540 2.3 106.7 HRVC-600-2 50.2 165.0 54.5 41.4 600 2.5 96.0 HRVC-720-2 60.4 198.0 65.5 49.7 720 3.0 80.0 HRVC-840-2 70.4 231.0 76.4 57.9 840 3.5 68.6 HRVC-960-2 80.4 264.0 87.3 66.2 960 4.0 60.0 HRVC-1080-2 90.6 297.0 98.2 74.5 1080 4.5 53.3 HRVC-1200-2 100.6 330.0 109.1 82.8 1200 5.0 48.0 HRVC-1280-2 110.8 363.0 116.4 88.3 1280 5.3 45.0 HRVC-1440-2 120.8 396.0 130.9 99.3 1440 6.0 40.0 HRVC-1560-2 130.6 429.0 141.8 107.6 1560 6.5 36.9 HRVC-1680-2 140.8 462.0 152.7 115.9 1680 7.0 34.3 HRVC-1920-2 161.0 528.0 174.5 132.4 1920 8.0 30.0 HRVC-2160-2 181 594 196.4 149.0 2160 9.0 26.7 HRVC-2400-2 201 660 218.2 165.5 2400 10.0 24.0 HRVC-2640-2 221.2 726 240.0 182.1 2640 11.0 21.8 HRVC-2880-2 241.4 792 261.8 198.6 2880 12.0 20.0 HRVC-3120-2 261.6 858 283.6 215.2 3120 13.0 18.5 HRVC-3360-2 281.6 924 305.5 231.7 3360 14.0 17.1 HRVC-3600-2 301.8 990 327.3 248.3 3600 15.0 16.0 Herein, 1 and 2 means the operation voltage, “1”=120V, “2”=240V

Learn More
Top
Leave A Message
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Home

Products

skype

whatsapp