bannerny

In Screed Underfloor Heating Cable I-cable

I-cable is a heating cable designed for new buildings applications or any other circumstances where screed is going to be laid.This system is usually installed on top of a layer of insulation beneath a 50-70 mm screed and the output can be varied when being installed to accommodate your specific circumstances.If an output of 160 W/m² is choosed, then any floor covering can be laid on top of the screed, making this a suitable system to install when final floor coverings have not been applied.

Loose Wire Heating Cable System
LOADING IMAGES
  • Item NO.:

    I-cable
  • Lead Time:

    20 days after received payment
  • Product Orgin:

    China
  • Brand:

    Huanrui
  • Shipping Port:

    Any port in China
  • Payment:

    FOB CFR CIF DDU DDP EXW
  • Color:

    OEM color
contact us now
Related products
  • Underfloor Heating System Thermostat Touch Screen Period Programming Thermostat E9

    Touch Screen Period Programming Thermostat Weekly circulation, it is possible to set 6 periods called events each day with corresponding pre-set temperatures, also you can select "period control mode" or "manual mode" according to your individual requirements. The thermostat is recommended for the control of electric heating devices or on/off valve1

  • Underfloor Heating System Thermostat Digital Thermostat E5

    Weekly Programming Thermostat with LCD Screen Weekly circulation, it is possible to set 6 periods called events each day with different temperatures, also you can select "manual mode" or "temporary control mode" according to your individual requirements. The thermostat is recommended for the control of electric heating devices or on/off valve actua1

  • Cable Strapping Floor Heating Cable Strapping

    The steel strip and fixer of a stainless steel belt and a regulating screw, which is used for fixing the explosion proof power supply connection box and other accessories in the pipeline.

  • Pipe Frost Protect Electric constant wattage pipe heating system PHC

    Pre-assembled and ready to install, the cable prevents pipes from freezing, keeping water flowing to -40°C. Using an energy saving thermostat, PHC cable operate on 230 volts AC and are suitable for use on water filled plastic and metal water pipes.

  • Self-regulating Heating Cable Accessories Power Junction Box

    Explosion proof power supply connection box used for connection of power cable and electric heating wire in explosion proof area. Generally fixed in the pipe. After matching with the electric heating system, it is suitable to use in the factory area and the two area explosive gas mixture T4 group field use. Explosion proof power supply connection b1

  • Self Limited Heating Cable Composite Sampling Analyzer Tube

    Corrosion protection sampling composite cable is an important part of the environment protection monitoring system. It is composed of inner core made of a group of corrosion protection resin tubes of high performance, self-regulating heating cable, constant power heating cable and compensating cable, insulation layer and flame retarded polythene (P1

  • Features & Benefits

Product Name: In Screed Underfloor Heating Cable -- I-cable


Commodity Introduction: 

I-cable is a twin conductor heating cable for ease of installation and has very low EMF. I-cable is a cable for in screed heating in new buildings and suitable for use for all kind of rooms and all kinds of coverings.



Type

voltage

Length/m

Output/W

Resistance/Ω

I-cable20-200

230

10

200

264.5

I-cable20-300

230

15

300

176.3

I-cable20-400

230

20

400

132.3

I-cable20-500

230

25

500

105.8

I-cable20-600

230

30

600

88.2

I-cable20-700

230

35

700

75.6

I-cable20-850

230

42.5

850

62.2

I-cable20-1000

230

50

1000

52.9

I-cable20-1200

230

60

1200

44.1

I-cable20-1400

230

70

1400

37.8

I-cable20-1600

230

80

1600

33.1

I-cable20-1800

230

90

1800

29.4

I-cable20-2000

230

100

2000

26.5

I-cable20-2200

230

110

2200

24

I-cable20-2400

230

120

2400

22

I-cable20-2600

230

130

2600

20.3

I-cable20-2800

230

140

2800

18.9

I-cable20-3100

230

155

3100

17.1



Technical Data: 

Cable construction: Twin conductor
Outer Insulation: PVC/Fluoropolymer
Conductor Insulation: Fluoropolymer
Shield: Al foil and Cu wire
Protective jacket: PVC
Connector: Out splice
Outside diameter: 5.0-5.8 mm
Rated voltage: 110-120 V, 220-240 V
Power output: 20 w/m
Resistance tolerance: +10/-5 %


Features:

20 w/m

Twin conductor heating cable

Very low EMF

Only one cold tail for ease of installation

Diameter 5.0-5.8mm

100% screened

 

Applications:

I-cable is a heating cable designed for new buildings applications or any other circumstances where screed is going to be laid.

This system is usually installed on top of a layer of insulation beneath a 50-70mm screed and the output can be varied when being installed to accommodate your specific circumstances.

If an output of 160W/m2 is chosen, then any floor covering can be laid on top of the screed, making this a suitable system to install when final floor coverings have not been applied.


MOQ: 50 pcs


Certificate:

Our I-cable have already got CE TUV EAC certificate, and can apply OEM service. More Self-Regulating Heating Cable Kits may meet your requirements.